standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, /ite-hearing-aids
standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, /ite-hearing-aids
Inquiry
standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, /ite-hearing-aids
standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, standard-environmental-processing-configuration-combining-12-fitting-channels-24-adjustable-bands-48-dsp-channels-dfbc-20-feedback-management-standard-environment-recognition-and-endr-20-up-to-20-db, 
Inquiry

L12-IF 12 Channel Digital Hearing Aid

Standard environmental-processing configuration combining 12 fitting channels, 24 adjustable bands, 48 DSP channels, DFBC 2.0 feedback management, Standard Environment Recognition and ENDR 2.0 up to 20 dB.

Request a Quote
  • Overview

Overview

Product Overview

The L12-IF is a 12 channel digital hearing aid developed for hearing aid distributors, audiology clinics, hearing centers, medical device importers and professional hearing care organizations that require the first Standard Environment Recognition configuration in the L-IF family.

Built on the ACOD2101 intelligent multi-core DSP platform, the model provides 12 independently adjustable compression and amplification channels, 24 independently adjustable bands and 48 DSP channels. ERAC 1.0 Context Analysis Based Intelligent Multi-Compression Technology with a Dual-Knee structure provides the compression foundation.

At this model level, feedback management changes to DFBC 2.0 Adaptive Feedback Cancellation with 2 levels. Standard Environment Recognition is included, together with Standard Transient Noise Management and Standard Wind Noise Management. ENDR 2.0 Environment Detection and Noise Reduction is specified at up to 20 dB.

For B2B buyers, L12-IF represents the main processing transition in the family. It moves beyond the lower AFC 2.0 / ENDR 1.0 configurations and introduces the Standard environmental-management platform used by the two upper models.

Standard Environment Recognition as the Core Product Transition

The defining feature of L12-IF is the introduction of Standard Environment Recognition.

L4-IF and L8-IF do not include Environment Recognition. L12-IF adds the Standard system and also includes Standard Wind Noise Management together with Standard Transient Noise Management.

This changes the product story from a basic fitting-capacity progression to a broader environmental-processing configuration.

For distributors evaluating a 12 channel digital hearing aid, that distinction is important because it creates a clear technical breakpoint in the portfolio. The product can be positioned through its environmental-management package, not simply through the increase from 8 to 12 fitting channels.

L16-IF retains this Standard environmental tier while expanding fitting, band and DSP capacity and changing Personalized Data Storage from Standard to Medium.

Professional Configuration: 12 / 24 / 48

L12-IF provides 12 independently adjustable compression and amplification channels, 24 independently adjustable bands and 48 DSP channels.

The ACOD2101 intelligent multi-core DSP platform supports this 12 / 24 / 48 architecture, while ERAC 1.0 Multi-Compression Technology with a Dual-Knee structure provides the compression framework.

For professional fitting teams, the larger structure creates additional adjustment capacity compared with L8-IF. For distributors, the progression is easy to communicate in catalogs and quotations:

  • L4-IF: 4 / 8 / 16
  • L8-IF: 8 / 16 / 32
  • L12-IF: 12 / 24 / 48
  • L16-IF: 16 / 32 / 64

For buyers considering a 12 channel digital hearing aid, the fitting structure and Standard environmental-processing package form two complementary selection criteria.

DFBC 2.0 and ENDR 2.0 Platform

Feedback management is provided by DFBC 2.0 Adaptive Feedback Cancellation with 2 levels together with SIW technology.

Noise reduction is provided by ENDR 2.0, specified at up to 20 dB. Standard Transient Noise Management and Standard Wind Noise Management are included.

This marks a clear processing transition from the AFC 2.0 and ENDR 1.0 configuration used in L4-IF and L8-IF.

For B2B technical comparison, the move to DFBC 2.0 and ENDR 2.0 gives distributors additional model-specific specifications for training, quotations and account discussions.

The model therefore occupies a clear role in the range: it introduces the processing platform that L16-IF later retains at a higher fitting and DSP capacity.

Electroacoustic Baseline for Procurement

L12-IF is specified with a maximum OSPL90 of 110 dB and HFA OSPL90 of 105 dB. Maximum FOG50 is 35 dB and HFA FOG50 is 29 dB.

RTG Target and RTG Measured are both 29 dB. Frequency range is 200–5000 Hz, battery current is 1.2 mA and EQ is 25 dB. THD at 500 Hz, 800 Hz and 1600 Hz is specified at 3%.

For distributors and importers, the shared electroacoustic profile provides consistent reference data for sample evaluation and procurement comparison.

For professional buyers evaluating a 12 channel digital hearing aid, the stable electroacoustic baseline makes the model-specific differences in fitting structure and environmental processing easier to assess.

Professional Fitting and Device Functions

L12-IF provides 1 selectable program and includes an Internal Sound Field Assessment System and Internal Audiometer System.

Additional functions include:

  • Adjustable Turn-on Delay
  • Occlusion Effect Management
  • Low Battery Power Notification
  • Adjustable Notification Volume
  • Volume Control
  • FM Interface Compatibility
  • Auto Phone Function
  • Memory After Power-off
  • Standard Personalized Data Storage
  • Nano Coating Technology

These functions provide clinics, hearing centers and distributors with a practical operating specification for assessment, fitting and routine device management.

B2B Portfolio Positioning

As a 12 channel digital hearing aid, L12-IF is suitable for distributors, importers and professional hearing care organizations that need the first Standard Environment Recognition model in the L-IF family.

Its product identity is centered on 12 fitting channels, 24 adjustable bands, 48 DSP channels, DFBC 2.0 with 2 levels, Standard Environment Recognition, ENDR 2.0 up to 20 dB, Standard Transient Noise Management, Standard Wind Noise Management and Standard Personalized Data Storage.

L12-IF establishes the upper processing platform of the family, while L16-IF extends fitting and DSP capacity within the same Standard environmental tier.

Technical Specifications

Specification L12-IF
Product Type Digital Hearing Aid
Channels 12
Adjustable Compression & Amplification Channels 12
Independent Adjustable Bands 24
DSP ACOD2101
DSP Channels 48
Compression Technology ERAC 1.0, Dual-Knee
Feedback Cancellation DFBC 2.0, 2 Levels
SIW Technology SIW
Environment Recognition Standard
Noise Reduction ENDR 2.0, Max. 20 dB
Transient Noise Management Standard
Wind Noise Management Standard
Selectable Programs 1
Internal Sound Field Assessment Yes
Internal Audiometer Yes
Adjustable Turn-on Delay Yes
Occlusion Effect Management Yes
Low Battery Notification Yes
Adjustable Notification Volume Yes
Volume Control Yes
FM Interface Compatible Yes
Auto Phone Function Yes
Memory After Power-off Yes
Personalized Data Storage Standard
Nano Coating Technology Included
Max. OSPL90 110 dB
HFA OSPL90 105 dB
Max. FOG50 35 dB
HFA FOG50 29 dB
RTG Target / Measured 29 / 29 dB
Frequency Range 200–5000 Hz
Battery Current 1.2 mA
THD @ 500 / 800 / 1600 Hz 3% / 3% / 3%
EQ 25 dB

FAQ

How does L12-IF differ from L8-IF?

L12-IF introduces Standard Environment Recognition, Standard Wind Noise Management, DFBC 2.0 and ENDR 2.0 while increasing fitting and DSP capacity.

Which feedback technology is included?

DFBC 2.0 Adaptive Feedback Cancellation with 2 levels is included together with SIW technology.

What is the ENDR specification?

ENDR 2.0 is specified at up to 20 dB.

How many selectable programs are included?

L12-IF provides 1 selectable program.

What data storage level is specified?

Personalized Data Storage is specified as Standard.

Contact AcoSound

Looking for a 12 channel digital hearing aid for your professional product portfolio? Contact AcoSound for L12-IF specifications, samples and B2B project support.

L12-IF 12 Channel Digital Hearing Aid

Standard environmental-processing configuration combining 12 fitting channels, 24 adjustable bands, 48 DSP channels, DFBC 2.0 feedback management, Standard Environment Recognition and ENDR 2.0 up to 20 dB.

Request a Quote

Featured Products

This is a title description that can briefly introduce the module.

standard environmental processing configuration combining 12 fitting channels 24 adjustable bands 48 dsp channels dfbc 20 feedback management standard environment recognition and endr 20 up to 20 db-2

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000