The highest fitting and DSP configuration in the C-RIC-S family, combining 32 channels, 128 DSP channels and five-level environmental noise management.
The C32-RIC-S is a 32 channel advanced RIC hearing aid positioned as the highest fitting-channel and DSP-channel configuration within the four-model C-RIC-S family.
Its ACOD2101 intelligent multi-core DSP platform provides 32 independently adjustable compression and amplification channels, 32 independently adjustable bands and 128 DSP channels.
The model retains the Intelligent environmental-processing architecture introduced with C24-RIC-S, including DFBC 3.0 Self-Adaptive feedback cancellation, Intelligent Environment Recognition and ENDR 3.0 noise reduction up to 25 dB.
Its principal progression comes from greater fitting capacity, greater DSP capacity and five-level transient and wind-noise management.
For professional buyers, these specifications provide a clear technical basis for positioning C32-RIC-S at the top of the product family.
C32-RIC-S provides 32 independently adjustable compression and amplification channels, the highest channel count among the four C-RIC-S configurations.
The number of independently adjustable bands remains at 32.
Compared with C24-RIC-S, fitting channels increase from 24 to 32 while the band structure remains unchanged.
This distinction is important for accurate technical comparison.
For hearing care professionals, the 32-channel architecture provides the largest fitting-channel configuration available in the range.
For distributors, this creates an easily communicated upper-tier specification without requiring changes to unrelated product claims.
The ACOD2101 processor provides 128 DSP channels in C32-RIC-S.
This compares with:
The progression provides a clear numerical structure across the family.
For B2B product planning, the 128-DSP configuration is one of the strongest measurable differences between C32-RIC-S and C24-RIC-S.
The DSP architecture supports the platform's compression, feedback management, environmental recognition and noise-management functions.
C32-RIC-S retains the same core Intelligent-level processing architecture used by C24-RIC-S.
The model includes:
Both models therefore share the same Intelligent environmental-processing platform.
The main differences between them are fitting-channel capacity, DSP capacity and the number of transient and wind-noise management levels.
This makes product comparison clearer for distributors and professional hearing care buyers.
C32-RIC-S provides the highest number of dedicated environmental-management levels in the family.
The model includes:
C24-RIC-S provides four levels for each function.
The increase from four to five creates another measurable difference between the two upper-tier configurations.
ENDR 3.0 remains specified at up to 25 dB of noise reduction.
Together with Intelligent Environment Recognition, these functions form the environmental-management package used in the highest configuration.
C32-RIC-S provides four selectable programs.
The product also includes an Internal Sound Field Assessment and Internal Audiometer, supporting professional fitting and assessment workflows.
Additional functions include:
These functions complement the higher fitting and DSP architecture and provide professional hearing care organizations with a structured device-management platform.
| Specification | C32-RIC-S |
|---|---|
| Product Type | Digital RIC Hearing Aid |
| Channels | 32 |
| Adjustable Compression & Amplification Channels | 32 |
| Independent Adjustable Bands | 32 |
| DSP | ACOD2101 |
| DSP Channels | 128 |
| Compression Technology | ERAC 2.0, Multi-Knee |
| Feedback Cancellation | DFBC 3.0 Self-Adaptive, 2 Levels |
| SIW Technology | DFBC + Advanced SIW |
| Environment Recognition | Intelligent |
| Noise Reduction | ENDR 3.0, Max. 25 dB |
| Transient Noise Management | Intelligent, 5 Levels |
| Wind Noise Management | Intelligent, 5 Levels |
| Selectable Programs | 4 |
| Personalized Data Storage | Advanced |
| Max. OSPL90 | 110 dB |
| HFA OSPL90 | 106 dB |
| Max. FOG50 | 35 dB |
| HFA FOG50 | 30 dB |
| Frequency Range | 200–4500 Hz |
| Battery Current | 1.25 mA |
| THD at 500 Hz | 3% |
| THD at 800 Hz | 3% |
| THD at 1600 Hz | 3% |
| Reference Test Gain – Target | 30 dB |
| Reference Test Gain – Measured | 30 dB |
| EQ | 25 dB |
The two higher configurations share many processing technologies, so their differences should be presented precisely.
| Specification | C24-RIC-S | C32-RIC-S |
|---|---|---|
| Fitting Channels | 24 | 32 |
| Adjustable Bands | 32 | 32 |
| DSP Channels | 96 | 128 |
| Transient Noise Management | 4 Levels | 5 Levels |
| Wind Noise Management | 4 Levels | 5 Levels |
Both models use DFBC 3.0 Self-Adaptive feedback management, Intelligent Environment Recognition and ENDR 3.0 with noise reduction up to 25 dB.
C32-RIC-S therefore provides greater fitting capacity, DSP capacity and noise-management levels while maintaining the same Intelligent environmental-processing platform.
C32-RIC-S is intended for hearing aid distributors, audiology clinics, hearing centers, medical device importers and professional hearing care networks requiring the highest specification tier within this family.
Its commercial position is supported by:
This gives distributors a transparent basis for positioning the product at the top of a multi-tier RIC portfolio.
It provides 32 independently adjustable compression and amplification channels, 32 adjustable bands and 128 DSP channels.
It increases fitting channels from 24 to 32, DSP channels from 96 to 128 and transient and wind-noise management from four to five levels.
The model uses Intelligent Environment Recognition.
ENDR 3.0 is specified at up to 25 dB.
C32-RIC-S uses DFBC 3.0 Self-Adaptive Feedback Cancellation with two levels.
Evaluating a professional 32 channel advanced RIC hearing aid for the upper tier of your product portfolio?
Contact AcoSound for C32-RIC-S specifications, samples and B2B project information.
The highest fitting and DSP configuration in the C-RIC-S family, combining 32 channels, 128 DSP channels and five-level environmental noise management.
This is a title description that can briefly introduce the module.