c12-if-12-channel-adaptive-hearing-aid, c12-if-12-channel-adaptive-hearing-aid, /ite-hearing-aids
Inquiry
Inquiry

C12-IF 12 Channel Adaptive Hearing Aid

Self-Adaptive C-IF configuration combining 12 fitting channels, 24 adjustable bands, 48 DSP channels, DFBC 3.0 Advanced feedback management, ENDR 2.0 noise reduction and two-level intelligent transient and wind noise management.

Request a Quote
  • Overview

Overview

Product Overview

The C12-IF is a 12 channel adaptive hearing aid developed for hearing aid distributors, audiology clinics, hearing centers, medical device importers and professional hearing care organizations that need a clearly defined starting configuration in the C-IF family.

Built on the ACOD2101 intelligent multi-core DSP platform, the model provides 12 independently adjustable compression and amplification channels, 24 independently adjustable bands and 48 DSP channels. ERAC 2.0 Context Analysis Based Intelligent Multi-Compression Technology with a Multi-Knee structure provides the compression foundation.

Feedback management is provided by DFBC 3.0 Advanced Feedback Cancellation with 2 levels together with DFBC+Advanced SIW technology. Environment Recognition is specified as Self-Adaptive. ENDR 2.0 Environment Detection and Noise Reduction is specified at up to 20 dB. Intelligent Transient Noise Management and Intelligent Wind Noise Management are both specified with 2 levels.

The model provides 4 selectable programs and includes an Internal Sound Field Assessment System and Internal Audiometer System. Personalized Data Storage is specified as Medium, and Nano Coating Technology is included.

For B2B buyers, C12-IF establishes the Self-Adaptive processing foundation of the C-IF range through a 12 / 24 / 48 fitting architecture, two-level noise-management structure and Medium Personalized Data Storage.

Self-Adaptive Processing Foundation

The core product identity of C12-IF is the combination of Self-Adaptive Environment Recognition and a defined two-level environmental noise-management structure.

For distributors evaluating a 12 channel adaptive hearing aid, this means the model can be positioned through more than channel count alone. Self-Adaptive Environment Recognition, ENDR 2.0 up to 20 dB, 2-level Intelligent Transient Noise Management and 2-level Intelligent Wind Noise Management create a documented set of processing specifications for product sheets and technical comparison.

This positioning is useful for a multi-model portfolio. C12-IF establishes the first Self-Adaptive configuration, C16-IF expands fitting and DSP capacity while increasing the two noise-management functions to 3 levels, and C24-IF moves into Intelligent Environment Recognition and ENDR 3.0.

For importers and distributors, the progression supports clearer product training, quotation preparation and sample evaluation. The technical story remains measurable at each step, reducing the need to rely on broad category language.

12 / 24 / 48 Professional Fitting Structure

C12-IF provides:

  • 12 independently adjustable compression and amplification channels
  • 24 independently adjustable bands
  • 48 DSP channels
  • ACOD2101 intelligent multi-core DSP
  • ERAC 2.0 Multi-Knee compression

The 12 / 24 / 48 configuration gives professional fitting teams a defined adjustment framework and gives distributors a concise numerical identity for catalog organization.

For buyers considering a 12 channel adaptive hearing aid, the fitting structure can be evaluated together with the environmental-processing package. That combination gives the model a distinct role before buyers move to the larger 16 / 32 / 64 configuration of C16-IF.

The family then continues to 24 / 32 / 96 and 32 / 32 / 128 in the Intelligent tier. This creates a straightforward capacity ladder for B2B buyers comparing several configurations within one product family.

Feedback and Noise Management

C12-IF uses DFBC 3.0 Advanced Feedback Cancellation with 2 levels. DFBC+Advanced SIW technology is included as part of the processing platform.

Noise reduction is provided by ENDR 2.0, specified at up to 20 dB. Intelligent Transient Noise Management and Intelligent Wind Noise Management are both specified with 2 levels.

For professional buyers evaluating C12-IF, these functions establish a practical baseline for the Self-Adaptive tier. The higher C16-IF retains the same feedback and Environment Recognition categories while increasing noise-management level count and fitting capacity.

This makes C12-IF especially useful as a reference configuration for distributors building a structured C-IF range with clearly separated technical steps.

Electroacoustic Benchmark for B2B Evaluation

C12-IF is specified with a maximum OSPL90 of 110 dB and HFA OSPL90 of 105 dB. Maximum FOG50 is 35 dB and HFA FOG50 is 29 dB.

RTG Target and RTG Measured are both specified at 29 dB. The frequency range is 200–5000 Hz, battery current is 1.2 mA and EQ is 25 dB. THD at 500 Hz, 800 Hz and 1600 Hz is specified at 3%.

For distributors and importers, these figures provide stable reference data for technical sheets, procurement review and sample comparison. Because the electroacoustic profile is shared across the C-IF family, model differentiation can focus on fitting capacity, feedback category, environment recognition and noise-management level count.

For buyers evaluating a 12 channel adaptive hearing aid, the electroacoustic benchmark therefore complements the 12 / 24 / 48 architecture without duplicating the role of the processing specifications.

Professional Device Functions

C12-IF provides 4 selectable programs and includes an Internal Sound Field Assessment System and Internal Audiometer System.

Additional functions include Adjustable Turn-on Delay, Occlusion Effect Management, Low Battery Power Notification, Adjustable Notification Volume, Volume Control and Memory After Power-off.

Personalized Data Storage is specified as Medium. Nano Coating Technology is included.

These functions provide clinics, hearing centers and distributors with a practical operating specification for assessment, fitting and routine device management.

B2B Portfolio Positioning

As a 12 channel adaptive hearing aid, C12-IF is suitable for distributors, medical device importers, audiology clinics and hearing centers that need the first Self-Adaptive configuration in the C-IF family.

Its product identity is centered on 12 fitting channels, 24 adjustable bands, 48 DSP channels, DFBC 3.0 Advanced with 2 levels, Self-Adaptive Environment Recognition, ENDR 2.0 up to 20 dB, two-level Intelligent transient and wind management, and Medium Personalized Data Storage.

This gives buyers a clear technical reference point before moving to the higher-capacity C16-IF or the Intelligent-tier C24-IF and C32-IF configurations.

Technical Specifications

Specification C12-IF
Product Type Digital Hearing Aid
Channels 12
Adjustable Compression & Amplification Channels 12
Independent Adjustable Bands 24
DSP ACOD2101
DSP Channels 48
Compression Technology ERAC 2.0, Multi-Knee
Feedback Cancellation DFBC 3.0 Advanced, 2 Levels
SIW Technology DFBC+Advanced SIW
Environment Recognition Self-Adaptive
Noise Reduction ENDR 2.0, Max. 20 dB
Transient Noise Management Intelligent, 2 Levels
Wind Noise Management Intelligent, 2 Levels
Selectable Programs 4
Internal Sound Field Assessment Yes
Internal Audiometer Yes
Adjustable Turn-on Delay Yes
Occlusion Effect Management Yes
Low Battery Notification Yes
Adjustable Notification Volume Yes
Volume Control Yes
Memory After Power-off Yes
Personalized Data Storage Medium
Nano Coating Technology Included
Max. OSPL90 110 dB
HFA OSPL90 105 dB
Max. FOG50 35 dB
HFA FOG50 29 dB
RTG Target / Measured 29 / 29 dB
Frequency Range 200–5000 Hz
Battery Current 1.2 mA
THD @ 500 / 800 / 1600 Hz 3% / 3% / 3%
EQ 25 dB

FAQ

How many fitting channels does C12-IF provide?

It provides 12 independently adjustable compression and amplification channels, 24 adjustable bands and 48 DSP channels.

Which Environment Recognition system is included?

Self-Adaptive Environment Recognition is included.

What is the ENDR specification?

ENDR 2.0 is specified at up to 20 dB.

How many transient and wind noise-management levels are specified?

Both Intelligent Transient Noise Management and Intelligent Wind Noise Management are specified with 2 levels.

What data storage level is included?

Personalized Data Storage is specified as Medium.

Contact AcoSound

Looking for a 12 channel adaptive hearing aid for your professional product portfolio? Contact AcoSound for C12-IF specifications, sample information and B2B project support.

C12-IF 12 Channel Adaptive Hearing Aid

Self-Adaptive C-IF configuration combining 12 fitting channels, 24 adjustable bands, 48 DSP channels, DFBC 3.0 Advanced feedback management, ENDR 2.0 noise reduction and two-level intelligent transient and wind noise management.

Request a Quote

Featured Products

This is a title description that can briefly introduce the module.

c12 if 12 channel adaptive hearing aid-2

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000